Regulation

AFS : ADJUSTABLE AIR FLOW SYSTEM

How does it work ?

AFS 100% capacity

For 100% air capacity:

1st stage double acting cylinder raises atmospheric air to 4 to 5 bar achieving the most important pressure ratio from 1 to 4 to 5 bar.
At full load 1st stage double action cylinder produces 100% of rated capacity to provide 100% air to the blow moulder.

AFS 55% capacity

For 55% air capacity:

1st stage double acting cylinder compresses air upward only.
AFS automatically unloads the lower part of the cylinder to match air flow required in the system.

Comparaison:

AFS OFFAFS ON

AFS : Adjustable air-flow system : savings in figures

Savings are immediate and start from day one.

  • Savings are immediate and start from day one
  • Up to 45 % savings on the kW power at the shaft during half load
  • Up to 5 % savings on apparent power

AF Model CE 6 Compressor Equipped With AFS 1700 m³/h – 315 kW Installed Power – 40 Bar Operating Pressure.

Graphe AFS
  • 100 % Load : 287 kW
  • 55% Load: 158 kW
  • 0% Load: 26.5 kW

FREQUENCY INVERTER – Full Size Package

decreasing the speed    increasing the savings
Following to your bottling production profile :
increasing efficiency + decreasing power consumption.
Speed adaption via frequency inverter.

  • frequency inverter electrical cabinet.
  • specific motor. Isolated bearings…
  • electrical pre-lubrication oil pump.
  • shielded cabling… other protection device.
  • LHF, Line Harmonic Filters.
Frequency inverter - Full size package

FREQUENCY INVERTER – VARIABLE SPEED

decreasing speed : increasing savings
  • Starting current of max 1,2 times nominal
  • Power factor (cos φ) between 0,95 and 1,0
  • Smooth start-up – no stress on the belts
    Reduces off-load times
  • Potential energy savings if air demand is fluctuating and more in the low end

SIS : Smart Inverter Starter

starting current  far below   nominal current

Specific Frequency Inverter electrical cabinet for starting purpose.
  • Standard electric motor…
  • Electrical pre-lubrication oil pump.
  • No shielded cabling… or other protection device required.
  • No LHF, Line Harmonic Filters required
SIS : Smart Inverter Starter
  •  Starting current even lower vs regular VSD.
  •  Starts faster than regular VSD.
  •  Full load power never exceeds 100 %.
SIS graphic